Zodiac, now part of Fluidra, makes some of the most common salt chlorinators in Mallorca. The Ei2 Expert, the TRi Expert and the eXO all use text messages and warning lights, and the wording is similar across the range. This guide explains the messages owners see most often, what usually causes them and what you can safely check before calling a technician. The wording changes with the language setting, so always compare the message with the manual for your model.
Salt: CHECK SALT, LOW CONDUCTIVITY and HIGH SALT
Zodiac recommends 4 g/L of salt for the Ei2 Expert, TRi Expert and eXO. The low-salt LS version of the eXO iQ runs on about 2 g/L.
- CHECK SALT (VERIFIER SEL or CONTROLER SEL in French) with an orange salt light: the salt is low or the water is cold. On the Ei2 Expert the warning appears below 3 g/L. On the TRi Expert it can also point to very hard water, a scaled or ageing electrode, or a flow or cable problem
- LOW CONDUCTIVITY on the eXO: salt below 4 g/L, cold water, or a scaled or worn cell
- HIGH SALT (SEL ELEVE) on the Ei2 Expert: salt above 10 g/L, usually after too much salt was added
Test the salt. If it is low, add salt to bring it back to 4 g/L and let it dissolve with the pump running. If it is high, partly drain and refill the pool. Cold water also lowers the reading: Zodiac's manuals mention salt warnings below about 18 °C, so in winter the message can appear even when the salt is right.
NO FLOW and PUMP FAULT
A red flow light with NO FLOW (AUCUN DEBIT on the Ei2 Expert, DEFAUT DEBIT or CONTROLER POMPE on the TRi Expert, NO FLOW / CHECK PUMP on the eXO) means the flow switch is not detecting water moving through the cell, so production stops for safety. Common causes:
- The filter pump is off or faulty, or its timer is set wrongly
- A dirty filter or full skimmer and pump baskets
- Closed by-pass valves around the cell
- A flow switch or cell cable that is unplugged or faulty
- Air or gas in the cell
Check the pump and timer, clean the baskets, backwash the filter and open the valves. If the flow is clearly good and the message stays, the flow switch or its wiring needs a technician. On the TRi Expert and the eXO you clear the message by holding the button for a few seconds once the cause is fixed.
Production faults: PROD, CHECK OUTPUT and CONTROLER CELL
- PROD on the Ei2 Expert: the cell is scaled or worn, or there is a short circuit
- CHECK OUTPUT on the eXO: the cell lead is disconnected, the plates are worn or calcified, or there is an electronic fault after an electrical incident
- CONTROLER CELL on the TRi Expert: a cell problem such as scale, age or a loose connection
- DEFAUT PROD on the TRi Expert: a production fault; hold the button for 3 to 4 seconds to clear it and call your dealer if it comes back
Start by switching off, checking the cell cable and looking at the plates for white scale. Clean the cell if it is scaled. If the message returns with a clean, well-connected cell, the electrode may be at the end of its life or the control box needs testing by a qualified technician.
OVERHEAT and LOW TEMPERATURE
- OVERHEAT (SURCHAUFFE): the control box is too hot. The Ei2 Expert halves its output above 70 °C inside the box and stops above 80 °C; the eXO slows down above 85 °C and stops above 90 °C. Production restarts once it cools. In a Mallorca summer the usual cause is a control box in direct sun or a hot, unventilated pump room, so shade or ventilate it
- LOW TEMPERATURE on the eXO: the water is at or below 10 °C, so the unit stops to protect the cell. It restarts at low output between 10 and 15 °C and runs normally above 15 °C. This is not a fault
INVERSION is information, not an error
INVERSION on the Ei2 Expert and TRi Expert means the unit is reversing the electrode polarity to shed calcium. Zodiac's manual says this is not an error code, only information, and production resumes by itself after about ten minutes. On the Ei2 Expert, a clock that keeps losing its time setting points to a flat CR2032 battery, which is easy to replace.
Cleaning a Zodiac cell
Polarity reversal reduces scale, but in Mallorca's hard water the cell may still need cleaning. Zodiac's European manuals describe it like this:
- Switch off the chlorinator and the filtration, close the isolation valves and disconnect the cell cable
- Remove the electrode and stand it with the plates in the liquid and the terminals dry
- Use a commercial cell cleaner, or 1 part hydrochloric acid to 9 parts water, always pouring the acid into the water and wearing protective equipment
- Soak for about 15 minutes, then rinse with clean water
- Take the used solution to an approved waste point, never into drains
In very hard water, above 40 °f or 400 ppm, your dealer can change the polarity reversal cycle. On the eXO, the manual says changing it without Zodiac or a professional voids the warranty.
When to call a technician
Book a technician when a message keeps coming back after you have fixed the salt and the flow, when the cell is clean but production stays low, or when the control box shows heat damage, water inside or a blank screen. Cells wear out: distributors quote around 7,500 hours for an Ei2 cell and around 10,000 hours for an eXO iQ, so a new cell after several seasons is normal. Our salt chlorinator repair page shows typical repair prices in Mallorca.